Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros








Base de dados
Intervalo de ano de publicação
1.
BMC Oral Health ; 24(1): 152, 2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-38297285

RESUMO

TRIAL DESIGN: Parallel. OBJECTIVE: To compare skeletally anchored Carriere Motion appliance (CMA) for distalization of the maxillary buccal segment vs. Essix anchored CMA. METHODS: Thirty-two class II malocclusion patients were randomly allocated into two equal groups. One group was treated with infrazygomatic (IZC) miniscrew- anchored CMA (IZCG) and the other group treated with Essix retainer- anchored CMA (EXG). Two lateral cephalograms and two digital models for upper and lower arches were taken for each patient: immediately before intervention and after distalization had been completed. RESULTS: Distalization period was not significantly different between the two groups. In contrast to EXG, IZCG showed insignificant difference in ANB, lower incisor proclination, and mesial movement of the lower first molar. There was significant rotation with distal movement of maxillary canine and first molar in both groups. CONCLUSION: IZC anchored CMA could eliminate the side effects of class II elastics regarding lower incisor proclination, mesial movement lower molars with a more significant amount of distalization of the maxillary buccal segment but with significant molar rotation. TRIAL REGISTRATION: The ClinicalTrials.gov Protocol Registration and Results System (PRS) has this RCT registered as (NCT05499221) on 12/08/2022.


Assuntos
Má Oclusão Classe II de Angle , Procedimentos de Ancoragem Ortodôntica , Humanos , Resultado do Tratamento , Técnicas de Movimentação Dentária/métodos , Maxila , Má Oclusão Classe II de Angle/terapia , Má Oclusão Classe II de Angle/etiologia , Cefalometria/métodos , Desenho de Aparelho Ortodôntico
2.
Artigo em Inglês | MEDLINE | ID: mdl-33575014

RESUMO

Background. The present study aimed to evaluate the bond strength of metal bracket (MB) and ceramic bracket (CB) bonded to different CAD/CAM ceramic substrates etched with hydrofluoric acid (HFA) vs. phosphoric acid (PA). Methods. A total of 120 CAD/CAM ceramic blocks in 12 groups were fabricated from three different CAD/CAM ceramic materials: VITABLOCS Mark II, VITAENAMIC, and IPS e.max CAD. Each ceramic material group was divided into two etching groups: one treated with 9.5% HFA and the other treated with 37%. Sixty metal and CBs of the upper right central incisor were bonded to the HFA-treated blocks. Another 60 metal and CBs were bonded to the PA treated blocks. All the bonded specimens were thermocycled before shear bond strength (SBS) testing. Then the bond failure mode was recorded Results. There were no significant differences in SBS values between the three CAD/CAM ceramic materials. The HFA-treated specimens exhibited significantly higher SBS values than the PA-treated specimens. Also, the SBS values of CBs were significantly higher than the metal brackets (MBs). The adhesive remnant index (ARI) score was 4 for most of the groups, indicating that almost no adhesive remained on the porcelain surface. Conclusion. The CAD/CAM ceramic type did not influence SBS; however, HFA exhibited significantly higher SBS compared to PA.

3.
Int J Orthod Milwaukee ; 25(4): 21-5, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25745706

RESUMO

OBJECTIVES: To evaluate dento-skeletal effects of the Pendulum Hygienic Distalizer (P.H.D), utilized on expansion of the maxillary arch and distalizing of maxillary first molars. MATERIAL AND METHODS: Ten patients were selected from the outpatient clinic of Department of Orthodontics, Faculty of Dentistry, Mansoura University having: (1) Skeletal Class I with moderate maxillary crowding; (2) Angle Class II molars relation; (3) Constricted maxillary arch (posterior crossbite); (4) Ages ranged from 11 to 14 years with an average age of 12 years and 2 months. The changes that, brought by the appliance were evaluated from the lateral cephalometric, postero-anterior radiographs and study cast model taken before and after appliance application by means of a paired t-test. RESULTS: Significant amounts of maxillary expansion, molar distalization, molar distal tipping and anchorage loss were observed. The amount of maxillary expansion was 4.35 ± 072 mm. The mean maxillary first molar distal movement was 2.27 ± 0.52 mm with a distal tipping of 1.71 ± 0.74 degrees in 3.19 ± 0.53 months. The rate ofdistal movement was 0.70 mm per month. Reciprocal mesial movement of the first premolars was 1.73 ± 0.92 mm with a mesial tipping of 2.60 ± 1.02 degrees. Maxillary incisors moved 1.80 ± 0.85 mm and tipped 2.02 ± 1.43 degrees mesially. CONCLUSIONS: It was concluded that the Pendulum Hygienic Distalizer works well with the treatment philosophy of Class II malocclusion with posterior cross-bite by expansion the maxillary arch and distalizing of maxillary molars.


Assuntos
Cefalometria/métodos , Desenho de Aparelho Ortodôntico , Técnica de Expansão Palatina/instrumentação , Adolescente , Dente Pré-Molar/patologia , Criança , Seguimentos , Humanos , Incisivo/patologia , Má Oclusão Classe I de Angle/terapia , Má Oclusão Classe II de Angle/terapia , Maxila/patologia , Modelos Dentários , Dente Molar/patologia , Osso Nasal/patologia , Sela Túrcica/patologia , Dimensão Vertical
4.
Int J Orthod Milwaukee ; 23(2): 51-6, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22873025

RESUMO

UNLABELLED: The objective of this study was to determine dental and skeletal effects of the jumper twin block appliance in the treatment of developing Class II, Division I malocclusion. METHODS: 15 girls aged 9 to 11 years old with class II division 1 and samephysical maturation status were included in the study over one year. Cephalometric data and study models were analyzed statistically with Paired t-test. RESULTS: The jumper twin block had skeletal and dental effects. Stimulation of forward mandibular growth, backward displacement of the maxilla, significant increase in the anterior and posterior facial height, retroclination of the upper incisors, proclination of the lower incisors and significant improvement of the overjet and overbite had been found. CONCLUSIONS: The jumper twin block appliance with gradual bite advancement was effective in treatment of developing Class II division 1 malocclusion.


Assuntos
Má Oclusão Classe II de Angle/terapia , Aparelhos Ortodônticos Funcionais , Ortodontia Interceptora/instrumentação , Criança , Feminino , Humanos , Desenho de Aparelho Ortodôntico
5.
Int J Orthod Milwaukee ; 21(4): 13-24, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-21314084

RESUMO

Angle Class II division 1 malocclusion has been one of the most encountered problems in the orthodontic practice. In growing patients, mandibular repositioning appliances are the method of choice to induce mandibular growth and are termed functional appliances. This study was carried out to investigate the possible effect of the Sabbagh Universal Spring2 (SUS2) on the dental and skeletal cephalometric measurements in the permanent dentition of ten growing patients with Class II division 1 malocclusion and to compare its effect with the similar available data of similar fixed functional appliances. It was concluded that the Sabbagh Universal Spring2 appliance works well with the treatment philosophy of Class II division 1 malocclusion with retruded mandible by advancing the mandible anteriorly.


Assuntos
Aparelhos Ativadores , Má Oclusão Classe II de Angle/terapia , Mandíbula/crescimento & desenvolvimento , Desenho de Aparelho Ortodôntico , Aparelhos Ortodônticos Funcionais , Adolescente , Determinação da Idade pelo Esqueleto , Cefalometria/métodos , Criança , Queixo/patologia , Feminino , Seguimentos , Humanos , Incisivo/patologia , Masculino , Má Oclusão Classe II de Angle/patologia , Mandíbula/patologia , Maxila/patologia , Osso Nasal/patologia , Sela Túrcica/patologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA